Top rated HMI factory
Top hmi touch screen panel manufacturer and supplier: Interaction design is subordinate to the product system and is a strong support and refinement to successful product design. If we use the system theory point of view, interaction design is a subsystem of the product design system. Design Principles: The following principles should be considered for the design of human machine interface. The basic user-centered design principle: In the design process of the system, designers should grasp the characteristics of users and discover the needs of users. Users’ opinions should be constantly sought and consulted throughout the development process of the system. The design decisions of the system should be integrated with the users’ work and application environment, and the users’ requirements for the system must be understood. The best way is to involve real users in the development, so that developers can properly understand the needs and goals of users, and the system will be more successful. See more information at hmi panel.
Reasonable Structural Type: There are two structural types: main module and extended module. The average price of each I/O point of the integral PLC is cheaper than that of the module type, and the volume is relatively small, which is generally used in the small control system with a fixed system process; The function expansion of module plc is flexible and convenient, and there is a large choice in the number of I/O points, the ratio of input points to output points, the type of I/O modules…etc, and the maintenance is convenient, generally in more complex control systems.
Consider the typical problems in interface design: To design any interface, we must generally consider four aspects: system response time, user help mechanism, error message handling and command mode. System response time is too long is the most complained about in the interactive system, in addition to the absolute length of the response time, the user is concerned about the difference in response time of different commands, if too much disparity in the user will be difficult to accept; user help mechanism should be integrated, to avoid the superimposed system leads to the user to help a guide and have to browse a lot of irrelevant information; error and warning information must be selected user understandable The error and warning messages must be user-friendly, accurate terminology, and should also provide some suggestions for error recovery as much as possible. In addition, the display of error information, if supplemented by auditory (ringing), visual (special color) stimulation, it is more effective; command mode is best to menu and keyboard commands coexist for the user to choose.
The reason is rs232 is suitable for communication between local devices, and its transmission distance is generally not more than 15m, and rs232 only allows one-ton-one communication. But rs485 transmission distance is from tens of meters up to 2Km, and rs485 interface allows up to 255 slave station to be connected. These are required to be designed by our engineers, with whom to communicate, how many devices to communicate, how to achieve the final function, whether to take into consider the interference problems of the field environment etc. All of the above are considered.
In 2022, in order to meet the new needs of customers and the market, our MochuanDrives merged with a professional manufacturer of highly customized servo motors, with more than 20 years of experience in research and development, manufacturing and service of servo motors and brushless motors, especially good at tailor-made high-end motors with special specifications from scratch, until the stable manufacturing of large quantities. With NO MOQ, before large quantities needing to get 100% stable quality confirmation from our customers. Discover additional details at https://www.mochuan-drives.com/.
Use a multimeter to determine the test wiring according to the pins in the wiring diagram. Verify that the RS485 and RS232C wiring is correct, touch screens differ from various PLC wiring. This can be viewed by referring to Maintenance Control (help documentation for PLC and touch screen communication line connections), which is the basic method for normal troubleshooting of communication problems. Next I show you how to bypass the touch screen problem – online simulation. When communication fails, some customers will guess that there may be a problem with the touch panel interface or a problem with the interface. Online simulation means bypassing the touch screen and using the PLC to connect directly to the computer. Using our configuration software, the communication cable from the PLC itself is connected to the computer and an online simulation is carried out to see if the project can communicate. This can be done with a numerical input element or switch to see if the operation before and after closing the simulator and opening the online simulation is still present and if it prompts a direct NC (NC and previous operations not written down are not connected).
Mochuan hmi suppliers offer free software, NO MOQ, fast shipment, to deal with us your payment and business are in safe. Offering one-to-one technical support online. The most important, our hmi wholesale is compatible with all brands of plc controllers, such as, Mitsubish FX2N, FX3U, FX3SA, FX5U…Siemens S7-200, S7-300, S7-400,…etc, ABB, Acrel, Allen-Bradley(AB), Delta, Fatek, Fuji, LS, Omron, Panasonic etc. To learn, please have a look our software, there is one list to show it.
There are lots of temperature control in industry automation. It can select temperature module match the main module plc temperature controller, it also use independent temperature controller to control, both of them are to achieve temperature control. If wanna more flexibility in temperature control, maybe indenpendent temperature module is the first choice. Becuase it can operate without main module plc controller. Mochuan independent plc temperature module integrates an excellent self-tuning algorithm, and user can auto-tune with one button according to needs to accurately obtain PID parameters. Through rs485 communication port, communicate with upper computers of various brands, types of plc, touch screen hmi, configuration software and other upper computers to complete morecomplex logic temperature control.
At the same time, because the electrical room has the characteristics of complex data processing, many inverters, strong voltage interference, and closed space, the requirements for the configuration, stability, and anti-interference of the body are high. The industrial-grade control equipment can be well integrated into the electrical cabinet control equipment, and can effectively control all electrical equipment, in the current era of big data and the Internet of Things, and even directly through remote control equipment, the electrical cabinet equipment monitoring.
Specifically, the two-way communication between the HCI user and the machine containing the computer, in a certain symbol and actions to achieve, such as hitting keys, moving the mouse, displaying symbols/graphics on the screen, etc. This process includes several sub-processes: identifying the interactive object – understanding the interactive object – grasping the object situation – information adaptation and feedback, etc.; and the human-machine interface is the communication media or means between the user and the machine system containing the computer, which is the software and hardware supporting the two-way information interaction between human and machine. Here the interface is defined as the media or means of communication, and its physical embodiment is the relevant supporting software and hardware, such as a graphic display terminal with a mouse, etc.