Dry type transformers supplier by Canwin: What does the rated value on the nameplate of the transformer mean? The rated value on the transformer nameplate refers to some important electrical parameters and performance indicators of the transformer. Usually includes the following aspects: Rated capacity: The rated capacity of a transformer refers to the maximum load electric power that the transformer can continuously supply. For example, a 10MVA transformer means that the transformer’s maximum load can reach 10 megawatts. Rated voltage: The rated voltage of the transformer refers to the design voltage of the transformer. For example, a 220kV/110kV transformer means that the input voltage of the transformer is 220 kV and the output voltage is 110 kV. Rated frequency: The rated frequency of a transformer refers to the power frequency for which the transformer is designed. In China, the power frequency is usually 50Hz. Short-time withstand current: The short-time withstand current of a transformer refers to the maximum current value that the transformer can withstand in a short period of time. For example, the short-term withstand current of a transformer is 50kA, which means that the transformer can withstand an instantaneous current of up to 50 kA. Discover extra information at core slitting machine.

Rising temperature: The capacity of the transformer will decrease as the temperature rises. Therefore, it is necessary to consider the appropriate heat dissipation method and heat dissipation area when designing the transformer to ensure that the temperature rise of the transformer does not exceed the allowable range. Connection method: Different transformer connection methods, such as star, delta, etc., will also affect the capacity of the transformer. For the star connection, the capacity of the transformer can be increased by about 3 times; for the delta connection, the capacity of the transformer is relatively small. Insulation level: The insulation level of the transformer determines the insulation capability and safety performance of the transformer, and also affects the capacity of the transformer. To sum up, the capacity of the transformer is related to factors such as input voltage and output voltage, load nature, temperature rise, connection method and insulation level. When selecting a transformer, it is necessary to comprehensively consider various factors according to the actual situation to ensure the normal operation and stability of the transformer.

In terms of productivity, poor PQ can cause unscheduled downtime due to equipment malfunctions or system failures. This unpredictability can significantly disrupt operations, leading to lower productivity levels and potential revenue losses. Moreover, poor PQ can lead to diminished energy efficiency. Transformers operating under poor power quality conditions often require more power to function, leading to increased energy consumption and higher operating costs. The excess power demand could also strain the electrical grid, leading to further inefficiencies and disruptions. Additionally, the costs associated with repairing or replacing damaged equipment due to poor power quality can be substantial. There are also indirect costs to consider, such as those associated with investigation and troubleshooting of power quality issues.

Canwin is a professional ctl line manufacturers & suppliers china, we have been specialized in ctl machines for over 20 years.This cut to length production line adopts advanced control system to ensure the accurate and stable operation of the cut to length production line. Embedded operating terminal can complete parameter setting quickly and conveniently. After the coil material of silicon steel sheet is punched and cut into certain shape and size by this cut to length production line, the classification and finishing work is completed at the end of the production line, and it is automatically stacked into 20 columns and used for the core assembly.

CANWIN adheres to the business policy of high -end manufacturing, intelligent equipment + intelligent factory, comprehensively improves the quality of products and the cutting speed and precision, accelerates the transformation of development mode, and promotes the upgrading of industrial structure In terms of new product development, the company relies on the “Guangdong university of technology provincial thin plate processing and cutting technology engineering center”as an innovation platform, continuously trains and introduces technological talents, and provides intellectual support for the company to enhance soft power and rapid development.

Oil immersed transformers are the most commonly used equipment mainly because of their simple structure and reliable operation. It has faster heat dissipation, uniform conduction, and better insulation performance than the dry-type transformer.Oil transformers are used in power distribution or electrical substations. Their transformer core and coils are immersed in oil, which cools and insulates. Oil circulates through ducts in the coil and around the coil and core assembly, moved by convection.

A transformer coil winding machine is an intricate piece of machinery with an essential role in the manufacturing of transformers, combining modern technology and meticulousness to create high-quality products efficiently. The process starts with the feeding of copper wire into the machine, which passes through a line-up of calibrations guides and tensioners designed to secure alignment and prevent damage. An automated system then causes rotation, gradually looping copper wire around the transformer coil. A computerized system oversees variables such as speed, pitch control, layer count and insulation thickness for consistent turns. Moreover, for distinct transformer models or designs, these machines can be fitted with extra features such as automatic lead cutting and tapping mechanisms for increased versatility and productivity.

As a result of mutual inductance, a transformer produces a transformed voltage or current when the magnetic flux produced by one winding (primary winding) links with another winding (secondary winding). There is a magnetic coupling between these two windings, and they are electrically isolated. In addition, magnetic reluctance is also known as opposition to magnetic flux flow. If, for example, the magnetic flux produced by a primary winding passes through air or any nonferrous material in order to reach a secondary winding in a transformer, it would result in a reduction in magnetic flux. Due to the high reluctance of air or nonferrous materials, it will reduce magnetic flux. Read extra information at canwindg.com

Epoxy resin is non – combustible, flame retardant, self – extinguishing solid insulation material, safe and clean. It is also a solid insulation material with proven insulation and heat dissipation technology for more than 40 years.Epoxy resin products can be used for dry type transformer, for insulation parts, for instrument transformer, for electrical composite parts and for room temperature curing. Epoxy resin dry transformer uses epoxy resin as insulation material. The high and low voltage windings are made of copper tape (foil), industrial epoxy resin is poured in vacuum and cured, forming a high strength FRP body structure. Insulation grade F, H. Epoxy resin dry transformer has the characteristics of good electrical performance, strong resistance to lightning impact, strong resistance to short circuit, small size and light weight. Temperature display controller can be installed to display and control the operating temperature of the transformer winding to ensure the normal service life of the transformer.

With the development of the times, people’s demand for power supply and the reliability of power supply are increasingly high, so the smart grid has emerged accordingly.In the power system, the core and hub of the substation is the transformer.The function of the transformer is mainly to distribute and convert electric energy. The normal operation of the transformer directly affects the normal function of the substation.The intelligent operation of the transformer mainly involves the protection and status monitoring of the transformer, so as to achieve real-time monitoring of the transformer and ultimately ensure the safety and reliability of power supply.

To accommodate the needs of grid voltage changes, the high-voltage side of the transformer has taps, which can be adjusted by adjusting the number of turns in the high-voltage winding to regulate the output voltage on the low-voltage side. Rated current (A): The current allowed to pass through the transformer for a long time under rated capacity. No-load loss (kW): The active power drawn when a rated voltage at rated frequency is applied to one winding terminal and the remaining windings are open circuit.It is related to the performance and manufacturing process of the core silicon steel sheet, as well as the applied voltage.